Summary table for area optimization.

SystemProcess temperature (°C)Solar energy penetration (%)Optimized area (m2) (%)

PVT6067.505.9267.41
7064.547.7264.50
8061.679.5461.76

FPC6061.795.2662.10
7059.296.7459.06
8056.598.2656.51

HPETC6069.144.9369.25
7066.686.2167.01
8064.957.5564.72

PVT-FPC6065.013.6465.10
7061.584.6261.63
8058.265.6758.30

PVT-HPETC6078.503.8578.40
7075.714.8175.30
8073.105.8173.06