Research Article
Comparative Evaluation of Liquid Cooling-Based Battery Thermal Management Systems: Fin Cooling, PCM Cooling, and Intercell Cooling
Table 6
Initial and optimized values of the input parameters and their ranges with the progress of OAAO.
| Step | V1 (mm) | V2 (mm) | V3 (mm) | V4 (mm) | V5 (mm) | H1 (mm) | H2 (mm) | H3 (mm) |
| Initial | 25 | 25 | 105 | 25 | 17.5 | 20 | 25 | 20 | 1st range | 10-40 | 10-40 | 60-150 | 10-25 | 15-40 | 15-25 | 15-35 | 15-25 | 2nd range | 38-40 | 38.5-40 | 60-150 | 10-25 | 38-40 | 20-25 | 15-28 | 15-25 | 3rd range | 38-40 | 38.8-40 | 60-150 | 10-20 | 38-40 | 21-25 | 15-28 | 15-25 | Optimal | 39.25 | 39.08 | 60.69 | 12.79 | 39.83 | 22.89 | 24.17 | 16.02 |
|
|