Research Article

Heat Transfer Performance Tests of a Circular-Fin Sodium-to-Air Heat Exchanger for Sodium-Cooled Fast Reactors

Table 2

M-FHX test matrix.

Test group no.Tube side (sodium)Shell side (air)
Flow rate (kg/s)Inlet temperature (°C)Flow rate (kg/s)Inlet temperature (°C)

(1)0.991870.12Atmospheric temperature (uncontrolled)
(2)1.063800.11
(3)1.503660.37
(4)1.503660.61
(5)1.503661.14
(6)2.193351.14
(7)2.193351.66
(8)2.193352.08
(9)2.194801.66
(10)2.194802.08
(11)2.743351.14
(12)2.743351.66
(13)2.743352.08
(14)2.743352.49
(15)3.294801.66
(16)3.294802.08
(17)3.293352.49