Research Article
A Novel Procedure for the AHP Method for the Site Selection of Solar PV Farms
Table 1
The criteria and subcriteria list and the related weights.
| Criterion | Weight | Subcriteria | Indicators | Criteria | Weight | Subcriteria | Indicators |
| Solar radiation rate | 36.92 | <1550 1550-1600 1600-1650 1650-1700 1700-1750 1750-1800 >1800 | 3 4 5 6 7 8 9 | Slope (%) | 10.44 | 0-3 3-6 6-9 9-12 12-20 >20 | 9 8 7 4 2 Restrained |
| Land use | 23.63 | Water Trees Flooded veg. Crops Built area Bare ground Snow/ice Rangeland | Restrained Restrained Restrained Restrained Restrained 8 Restrained 9 | Distance to road (km) | 6.08 | 0-0.01 0-1 1-2 2-4 4-8 8-16 >16 | Restrained 9 8 7 6 4 2 |
| Distance to transmission line (km) | 18.21 | 0-1 1-2 2-4 4-8 8-16 >16 | 9 8 7 6 4 2 | Distance to residential area (km) | 4.72 | 0-0.1 0.1-2.5 2.5-7.5 7.5-15 15-30 >30 | Restrained 9 7 5 3 1 |
|
|