Research Article

Optimal PMU Placement for Fault Classification and Localization Using Enhanced Feature Selection in Machine Learning Algorithms

Table 4

Sampling error for ROCOF in voltage at bus 1.

V1 ROCOFSamples/cycle6432168421
Fault typeFault locationError (Hz/s)

1100.1660.5650.9060.1220.41022.747
200.2760.3540.9490.97713.985
300.0000.0810.0560.0315.857
400.0390.0230.2180.7990.352
500.3451.3963.1705.835
600.1350.3690.8470.3730.055
700.0690.0690.2300.9255.972
800.1200.1201.6391.4171.53221.174
900.1010.3640.4480.5640.62718.719
1000.0000.4090.4700.5326.479