Research Article

An Enhanced MPPT Approach Based on CUSA for Grid-Integrated Hybrid Electric Vehicle Charging Station

Table 3

Result analysis and efficiency calculation.

AlgorithmSettling time (s)Power received avg. (W)Efficiency

CUSA0.051998.6099.26
FSSO0.421625.8081.29
PSO0.321746.8087.32