Research Article
Active Flow Control of the Magnetohydrodynamic Flow in an Annular Linear Induction Pump by Modifying the Driving Electromagnetic Field
Table 1
Main parameters of the numerical model (liquid sodium at 220°C) [
6].
| | Parameters | Values |
| | Simulated flow rate (m3/min) | 5.3 | | Radius of the center of the flow channel (m) | 0.148 | | Height of the flow channel (m) | 0.012 | | Total length of the ALIP (m) | 1.450 | | Density of liquid sodium (kg/m3) | 898.25 | | Conductivity of liquid sodium (S/m) | | | Kinetic viscosity of liquid sodium (m2/s) | | | Relative magnetic permeability of liquid sodium | 1 |
|
|