Research Article
Measurements and Design Calculations for a Deep Coaxial Borehole Heat Exchanger in Aachen, Germany
Table 1
Comparison thermal power of RWTH-1 BHE with Geothermal Aachener springs.
| Source | RWTH-1 | Geothermal Spings |
| Flow rate (m3/h) | 4 | 175 | Usage (h/d) | 9 h/d | 24 h/d | Temperature (°C) | 50 | 60 | Thermal power | | | Direct use (60°C to 25°C) (kW) | 117 | 7146 | Bathing or heat pump (25°C to 10°C) (kW) | 70 | 3062 |
|
|