Research Article
Pulmonary Nodule Detection from 3D CT Image with a Two-Stage Network
Table 3
Detection sensitivity and the CPM score achieved with different loss functions.
| Loss functions | 1/8 FPs/scan | 1/4 FPs/scan | 1/2 FPs/scan | 1 FPs/scan | 2 FPs/scan | 4 FPs/scan | 8 FPs/scan | CPM |
| Focal loss | 0.784 | 0.837 | 0.863 | 0.899 | 0.916 | 0.942 | 0.954 | 0.885 | MCE loss | 0.833 | 0.870 | 0.898 | 0.921 | 0.938 | 0.951 | 0.960 | 0.910 |
|
|