Pulmonary Nodule Detection from 3D CT Image with a Two-Stage Network
Table 4
Detection sensitivity and the CPM score achieved by different methods.
| Methods | 1/8 FPs/scan | 1/4 FPs/scan | 1/2 FPs/scan | 1 FPs/scan | 2 FPs/scan | 4 FPs/scan | 8 FPs/scan | CPM |
| NoduleNet (2020) [26] | 0.732 | 0.763 | 0.818 | 0.875 | 0.893 | 0.917 | 0.928 | 0.846 | S4ND (2019) [14] | 0.781 | 0.822 | 0.85 | 0.898 | 0.928 | 0.943 | 0.955 | 0.882 | DBResNet (2020) [13] | 0.817 | 0.852 | 0.885 | 0.912 | 0.936 | 0.947 | 0.955 | 0.900 | V-Net (2020) [15] | 0.702 | 0.801 | 0.844 | 0.881 | 0.927 | 0.939 | 0.942 | 0.862 | H-DenseUNet (2018) [22] | 0.753 | 0.802 | 0.832 | 0.88 | 0.909 | 0.935 | 0.953 | 0.866 | Swin-UNetr (2021) [27] | 0.761 | 0.827 | 0.867 | 0.902 | 0.933 | 0.949 | 0.956 | 0.885 | UNetr (2022) [28] | 0.726 | 0.754 | 0.801 | 0.853 | 0.878 | 0.912 | 0.937 | 0.837 | Ours | 0.833 | 0.87 | 0.898 | 0.921 | 0.938 | 0.951 | 0.96 | 0.910 |
|
|
The best results are highlighted in bold.
|