Research Article
A Dual-Band Dual-Output Filtering Power Amplifier Based on High-Selectivity Filtering Impedance Transformer
Table 2
Comparison of filtering impedance transformers.
| Ref. | Termination impedance | TZs | TPs | | FBWs (%) | CL num. | Stub num. |
| [3] | High | 4 | 2 | 4/6/8/10 | NA/NA/7.3a/NA | 1 | 1 | [4] | High | 4 | 3 | 8/10/12 | NA/19b/NA | 2 | 1 | [5] | Low | 6 | 3 | 5/10 | 19.85b/7.96b | 1 | 2 | [7] | Low/high | 4 | 2 | 25/71.43 | 5.065a/3.25a | 1 | 1 | [9] | Low | 4 | 3 | 2/5/10 | 22a/22a/22a | 2 | 1 | This work | High | 4 | 2 | 2/4/6 | 8.2a/12.2a/16.3a | 2 | 2 |
|
|
Two FITs are designed. a20 dB RL. b dB. The CLs used to realize impedance transformation and the CLs used as stubs are not concluded. |