Research Article
Development and Optimization of a Multiplex Real-Time RT-PCR to Detect SARS-CoV-2 in Human Samples
Figure 2
Amplification curves of different numbers of SARS-CoV-2 genome copies to evaluate the limit of detection (LoD). (a) Detection of 1 viral copy/μL (5 copies per reaction). (b) Detection of 2 viral copies/μL (10 copies per reaction). (c) Detection of 5 viral copies/μL (25 copies per reaction). (d) Detection of 10 viral copies/μL (50 copies per reaction). Reactions were performed in a BioRad CFX96 Thermocycler.
(a) |
(b) |
(c) |
(d) |