Research Article

Flow-Through Portable Antivirus UV-C Optical Enclosures to be Used with Protective Masks

Table 1

Lamp irradiance measurements from different distances and power calculations based on Keitz formulation.

Distance (mm)Irradiance (μW/cm2)Total power (W)Efficiency (%)

100128.00.1405.19
15059.00.1385.11
20034.00.1405.19
30015.50.1405.19