Research Article

Comparison Study of Two Different Sun-Tracking Methods in Optical Efficiency of Heliostat Field

Table 2

Annual efficiencies of heliostat field for both sun-tracking methods.

LatitudeSEAE
15° N30° N15° N30° N

Cosine efficiency84.99%84.45%82.86%84.99%84.45%82.86%
Blocking efficiency98.14%98.07%98.03%97.11%97.13%97.24%
Shadowing efficiency98.71%98.11%95.63%98.56%97.93%95.41%
Annual field efficiency, 82.33%81.25%77.67%81.35%80.33%76.88%