Research Article
The Evaluation of Solar Contribution in Solar Aided Coal-Fired Power Plant
Table 2
Main parameters of the collector field.
| | Parameters | Values | Units |
| | Solar irradiation | 925 | W/m2 | | Area of per collector | 235 | m2 | | Number of collector in each row | 16 | | | Rows of collectors | 30 | Rows | | Inlet temperature of heat transfer oil | 250 |
°C | | Outlet temperature of heat transfer oil | 328 |
°C |
|
|