Research Article

Analyzing Thermal Module Developments and Trends in High-Power LED

Table 3

Comparisons between experimental and numerical temperatures of A.C. 30 W ( °C).

CH123456789101112131415

Measured data (°C)41.041.841.441.339.939.942.341.637.446.946.845.445.664.454.1
Simulation result (°C)39.939.840.040.638.739.339.339.944.8XX44.242.962.653.8
Error (%)−2.6−4.7−3.3−1.6−3−1.5−7−414.4XX−2.6−5.9−2.4−0.5