Simulation results for energy consumption of HVAC systems for the building body in London, UK.

ModuleCooling energy consumption (kW)Cooling energy saving (%)Heating energy consumption (kW)Heating energy saving (%)Total HVAC system energy consumption (kW)Total HVAC energy saving (%)

Tandem laser module306116818117123
Tandem laser-A HISG18140.857120339.057138439.05
Tandem laser-B HISG17144.127057039.597074139.60
Tandem laser-C HISG17343.467049139.667066439.67

Tandem TCO module271117612117883
Tandem TCO-A HISG17037.277149739.217166739.20
Tandem TCO-B HISG16439.487075339.847091739.84
Tandem TCO-C HISG16539.117073439.867089939.86

a-Si TCO module287117214117501
a-Si TCO-A HISG17539.027127339.197144839.19
a-Si TCO-B HISG17240.077064039.737081239.73
a-Si TCO-C HISG17140.427056639.807073739.80