Research Article

E. coli Inactivation Kinetics Modeling in a Taylor-Couette UV Disinfection Reactor

Figure 6

Axial velocity profiles at different angular velocities (at left, from bottom to top: 300, 600, 1200, and 2000 rpm, respectively) evaluated in the middle of a toroidal vortex height as a function of the annular gap distance (-direction, from 0 to 0.01 m).