Research Article
E. coli Inactivation Kinetics Modeling in a Taylor-Couette UV Disinfection Reactor
Table 1
The effect of bacteria concentration and angular velocity on the kinetics of UV microbial inactivation.
| (rpm) | Inactivation rate constant (s-1) | | Efficiency removal (%) | Exposure time (s) |
| 33,000 PFU mL-1 | 0 | | 0.9671 | 63 | 900 | 300 | | 0.9833 | 67 | 900 | 600 | | 0.9795 | 79 | 900 | 2000 | | 0.9804 | 83 | 900 | 400,000 PFU mL-1 | 0 | | 0.995 | 66 | 1200 | 300 | | 0.988 | 73 | 1200 | 600 | | 0.998 | 78 | 1200 | 1200 | | 0.9580 | 80 | 1200 | 2000 | | 0.9870 | 83 | 1200 | 30,000,000 PFU mL-1 | 0 | | 0.9933 | 98 | 2700 | 300 | | 0.9756 | 100 | 2700 | 600 | | 0.9870 | 100 | 2700 |
|
|