Research Article

Optimal Sizing of Isolated Microgrid Containing Photovoltaic/Photothermal/Wind/Diesel/Battery

Table 1

Comparison of performance indicators of 3 algorithms.

Algorithm (problem)GDHVΔ
MeanVarianceMeanVarianceMeanVariance

NSGA-II(DTLZ1)0.19470.15930.68730.05030.85960.0238
MOGWO(DTLZ1)0.05390.03980.72110.05510.70120.0162
IMOGWO(DTLZ1)0.02540.05120.75830.04220.51250.0089
NSGA-II(DTLZ2)0.21970.43640.62420.07540.96490.1332
MOGWO(DTLZ2)0.02150.02370.67540.06090.87970.2505
IMOGWO(DTLZ2)0.01820.02180.70050.07940.50140.0218