Research Article

Modeling and Analysis of Energy/Exergy for Absorber Pipes of Linear Parabolic Concentrating Systems

Table 1

Model validation with thermal efficiency.

Length of absorber pipe (m) (%) [9] (%)Deviation (%)

350659
455.65011
540.2400.5