Research Article

Utilization of Rooftop Solar Units to Generate Electricity and Hydrogen: A Technoeconomic Analysis

Table 1

Technical and economic specifications of the components.

ComponentSize/numberLifetime (yr)Capital costReplacement costO & M costOther characteristics

RSUs8.2 (kW)251,560 ($/kW)1,530 ($/kW)10 ($/kW.yr)Electrical bus: AC
Derating factor: 96%
Temperature coefficient: -0.41 (%)
Operating temperature: 45 ()
Efficiency: 17.3%
Ground reflectance: 20%
Tracking system: no tracking
Converter1 (kW)15600 ($/kW)600 ($/kW)10 ($/kW.yr)Rectifier efficiency: 90%
Inverter efficiency: 95%
Rectifier relative capacity: 100%
Storage1(#)103,200 ($/#)3,000 ($/#)20 ($/#.yr)Throughput: 80,000 (kWh)
Nominal voltage: 240 (V)
Nominal capacity: 8 (kWh)
Nominal capacity: 33.3 (ah)
Roundtrip efficiency: 86%
Maximum charge current: 15 (A)
Maximum discharge current: 15 (A)
Initial state of charge: 100%
Electrolyzer1 (kW)151,450 ($/kW)1,450 ($/kW)60 ($/kW.yr)Electrical bus: DC
Efficiency: 85%
Minimum load ratio: 55%
Hydrogen tank20 (kg)25120 ($/kg)120 ($/kg)5 ($/kg.yr)Initial tank level: 0