Research Article
Utilization of Rooftop Solar Units to Generate Electricity and Hydrogen: A Technoeconomic Analysis
Table 1
Technical and economic specifications of the components.
| Component | Size/number | Lifetime (yr) | Capital cost | Replacement cost | O & M cost | Other characteristics |
| RSUs | 8.2 (kW) | 25 | 1,560 ($/kW) | 1,530 ($/kW) | 10 ($/kW.yr) | Electrical bus: AC Derating factor: 96% Temperature coefficient: -0.41 (%) Operating temperature: 45 () Efficiency: 17.3% Ground reflectance: 20% Tracking system: no tracking | Converter | 1 (kW) | 15 | 600 ($/kW) | 600 ($/kW) | 10 ($/kW.yr) | Rectifier efficiency: 90% Inverter efficiency: 95% Rectifier relative capacity: 100% | Storage | 1(#) | 10 | 3,200 ($/#) | 3,000 ($/#) | 20 ($/#.yr) | Throughput: 80,000 (kWh) Nominal voltage: 240 (V) Nominal capacity: 8 (kWh) Nominal capacity: 33.3 (ah) Roundtrip efficiency: 86% Maximum charge current: 15 (A) Maximum discharge current: 15 (A) Initial state of charge: 100% | Electrolyzer | 1 (kW) | 15 | 1,450 ($/kW) | 1,450 ($/kW) | 60 ($/kW.yr) | Electrical bus: DC Efficiency: 85% Minimum load ratio: 55% | Hydrogen tank | 20 (kg) | 25 | 120 ($/kg) | 120 ($/kg) | 5 ($/kg.yr) | Initial tank level: 0 |
|
|