Research Article

Utilization of Rooftop Solar Units to Generate Electricity and Hydrogen: A Technoeconomic Analysis

Table 3

Present worth and annualized value of all costs over 10 years.

ComponentNet present costs ($)Annualized costs ($/yr)
CapitalReplacementO & MSalvageTotalCapitalReplacementO & MSalvageTotal

PV array12,79201,231-15,190-1,167852082-1,012-78
Storage3,200030003,5002130200233
Converter6000151-40434740010-2723
System16,59201,682-15,5942,6801,1050112-1,039178