Research Article

Utilization of Rooftop Solar Units to Generate Electricity and Hydrogen: A Technoeconomic Analysis

Table 5

Present worth and annualized value of all costs over 30 years.

ComponentNet present costs ($)Annualized costs ($/yr)
CapitalReplacementO & MSalvageTotalCapitalReplacementO & MSalvageTotal

PV array12,79272,5678,728-82,46611,62112068282-775109
Storage3,20018,2692,129023,59830172200222
Converter6001,7201,06403,38461610032
System16,59292,55611,921-82,46638,603156870112-775363