Research Article

A Seventeen Multilevel High-Power Application Inverter with Low Total Harmonic Distortion

Table 3

Circuit component values used in simulation and experimental setup.

S. no.ComponentValue

1Vin220 volts
2Lf5 mH
3Lb200 uH
4C1&C2330 nF
5Cbus10 nF
6Lm100 uH
7Cr30 nF
8Lr20 uH
9Co10 nF
10Switching frequency10 Hz