Test results of the average mechanical property.
| Run | Fiber loading (%) | Matrix loading (%) | Filler loading (%) | Tensile strength (MPa) | Compression strength (MPa) | Flexural strength (MPa) |
| 1 | 10 | 85 | 5 | 81.625 | 1219.42 | 1067.59 | 2 | 1 | 85 | 14 | 21.595 | 424.387 | 834.514 | 3 | 9 | 78 | 13 | 73.4725 | 1374.43 | 1041.78 | 4 | 10 | 80 | 10 | 76.827 | 1314.04 | 1053.15 | 5 | 6 | 81 | 13 | 65.734 | 987.79 | 972.649 | 6 | 4 | 85 | 11 | 62.525 | 678.901 | 935.053 | 7 | 10 | 74 | 16 | 70.0963 | 1690.82 | 1051.26 | 8 | 4 | 76 | 20 | 45.9984 | 898.371 | 920.256 | 9 | 4 | 79 | 17 | 57.445 | 788.434 | 910.234 | 10 | 0 | 82 | 18 | 12.9205 | 360.867 | 809.754 | 11 | 10 | 70 | 20 | 69.9525 | 1876.14 | 1049.74 |
|
|