Research Article
Design and Performance Evaluation of a Very Low Flow Coefficient Centrifugal Compressor
Table 3
Performance comparison between CFD and 1D code at design point.
| | | CFD | 1D (no parasitic losses) | 1D (parasitic losses) |
| | Power | 1778400 W | 1656740 W | 1857339 W | | π
tot | 1.21 | 1.1731 | 1.1731 | | η | 90.2% | 91.72% | 82.57% |
|
|