Research Article
A Visualized Method of Airflow between Adjacent Zones inside a Multizone Building Based on Pressure Difference Frequency: Airflow Mapping
Table 1
Instrument specifications.
| Instrument | Picture | Specifications |
| Pressure monitoring system A (data receiver and logger) | | Communication: RF communication | Function: receive real-time measured data from multiple B systems |
| Pressure monitoring system B (pressure sensors) | | Model: model PTB110 | Range: 800 to 1100 hPa | Accuracy: ±0.30 hPa at +20°C | Repeatability: ±0.03 hPa | Interval: 5 s (minimum) | Storage: 8 GB | Function: monitor real-time absolute pressure and communicate with system A |
| Absolute pressure gauge (standard absolute pressure) | | Model: model PTB330 class A | Range: 500 to 1100 hPa | Accuracy: ±0.10 hPa at +20°C | Repeatability: ±0.03 hPa | Function: monitor real-time absolute pressure and provide standard value |
|
|