Research Article
Effects of Ionization on the Filtration of Fine and Ultrafine Particles in Indoor Air
Table 2
Combined diffusion and interception average efficiency data.
| | Control | Treatment 1 | Treatment 2 | Treatment 3 | Average treatment |
| Overall | 0.87 | 0.99 | 0.97 | 0.98 | N/A | 0.3-1 micron | 0.384 | 0.899 | 0.888 | 0.887 | 0.892 | 1-3 micron | 0.847 | 0.965 | 0.930 | 0.946 | 0.947 | 3-10 micron | 0.949 | 0.965 | 0.930 | 0.946 | 0.947 |
| MPPS value (microns) | 0.2956 | 0.3417 | 0.3421 | 0.3403 | 0.3414 | MPPS efficiency | 0.221 | 0.797 | 0.818 | 0.790 | 0.802 |
|
|