Research Article

Development of a Bioaerosol Sampling Method for Airborne Pathogen Detection with Focus on SARS-CoV-2

Table 6

Results of qPCR analysis from the air samples collected with the Coriolis μ at the two daycare facilities (Ct values shown are for SARS-CoV-2; the presence of other pathogens is indicated by superscript numbering).

Week 1Week 2
Day 1Day 2Day 3Day 4

C1Playing roomMLV (CT 36.55)1NegativeLV (CT 36.99)Positive (, CT 33.86)5
ANegativeLV (CT 34.66)Negative
BedroomANegative2LV (CT 35.33)3

C2Ground floor roomMNegativeNegativeLV (CT 36.16)LV (CT 39.82)
ANegativeNegative4Negative
1st floor roomMNegativeNegativeNegativeLV (CT 36.82)6
ANegativeNegative

LV = limit value. Ct > LoB: increased possibility of false-pos; vl = viral load; M = sample collected in the morning; A = sample collected in the afternoon. 1Streptococcus pneumoniae DNA positive (). 2Streptococcus pneumoniae DNA positive () + coronavirus OC43 RNA at LV (). 3Streptococcus pneumoniae DNA positive () + rhinovirus positive (). 4Influenza A virus RNA at LV ( CDC/38 Schülze). 5Streptococcus pneumoniae DNA positive () + rhinovirus positive () + influenza A virus RNA at LV ( CDC/41 Schülze) + enterovirus RNA at LV (). 6Rhinovirus positive ().