Effects of Window Position and Exhaust Flow Rate on Residential Kitchen Hood Performance: A Validated Numerical Approach

Table 1

Parameters and their values for the boundary conditions.

BoundaryTypeFlow parameterTemperatureAir : CO2 volume fraction

Hood outletVolume outletLow: 6.72 m3/min
High: 12.16 m3/min
CO2 inletVolume inlet0.00036 m3/min26.5°C0 : 1
Nebulizer inletVolume inlet0.011 m3/min26.5°C0.9996 : 0.0004
Mixture fanVolume inlet/outlet0.566 m3/min26.5°C0.9994 : 0.0006
WindowsPressure openings101325 Pa26.5°C0.9996 : 0.0004
Ceiling openingPressure openings101325 Pa26.5 °C0.9996 : 0.0004
BoundaryTypeMaterialsTemperature
Heating coilWallCopper350°C
WallWallCast concrete
Heating chamberWallAISI 304
System structureWallAluminum 6061
Exhaust hoodWallAISI 304
Human modelWallPVC