Research Article

[Retracted] Nondestructive Testing of Coal Mine Wire Ropes Based on Magnetic Sensors

Table 3

The relationship between fatigue damage and magnetic parameters.

CyclesSaturation magnetic inductionRemanenceResidual strength

12176.4771.370.2
32173.2766.867.3
52171.8763.565.5
72170.1761.463.1
92168.3760.262.2
112164.9759.361.4
132162.1757.660.6
152160.7755.859.3
172158.5753.758.0