Research Article
An Enhanced Modified Multiport Interleaved Flyback Converter for Photovoltaic-Shunt Active Power Filter (PV-SHAPF) Applications
Table 2
System parameters of the simulated model.
| Description | Value | Description | Value |
| Rated power | 500 W | Switching frequency | 25 kHz | PV voltage | 12 V | DC bus voltage | 600 V | PV short circuit current | 28.55 a | DC link capacitor | 1000 μF | Supply frequency | 50 Hz | Capacitors CAx and CBx | 0.265 μF | Supply voltage | 400 V | Inductors LA and LB | 0.123 μH | Turns ratio | 1 : 2 | Power rating of the inverter | 1000 VA | Primary 1 and 2 voltage | 150 V | Inductor L1 and L2 | 11 μH | Secondary voltage | 600 V | Load resistance | 240 Ω/480 Ω |
|
|