Research Article

Compressed-DMD for Electromechanical Mode Estimation from High-Dimensional Ambient Data

Table 6

Identified results of modal parameters of the real measurement system.

ModeMethodFrequency/HzDamping ratio/%
MeanVarianceMeanVariance

1Compressed-DMD0.28837.23
SSI0.27870.006815.630.0068

2Compressed-DMD0.86657.48
SSI0.90080.028510.950.0074