Research Article

Fuzzy-Based EV Charging Station and DVR-Fed Voltage Compensation for a DFIG-Fed Wind Energy System during Grid Faults

Table 6

DFIG machine ratings.

DFIG characteristicsValue

Power2.5 MW
Stator voltage690 V
Stator current1760 A
Frequency50 Hz
Stator connectionStar
Rotor connectionStar
Poles2
Rs2.6e − 3 Ω
Ls0.087e − 3 H
Lm2.5e − 3 H
Rr2.9e − 3 Ω