Research Article
Fuzzy-Based EV Charging Station and DVR-Fed Voltage Compensation for a DFIG-Fed Wind Energy System during Grid Faults
| DFIG characteristics | Value |
| Power | 2.5 MW | Stator voltage | 690 V | Stator current | 1760 A | Frequency | 50 Hz | Stator connection | Star | Rotor connection | Star | Poles | 2 | Rs | 2.6e − 3 Ω | Ls | 0.087e − 3 H | Lm | 2.5e − 3 H | Rr | 2.9e − 3 Ω |
|
|