Research Article
Grid-Tied Hybrid AC-DC Microgrid: Finding Optimal Number of Parallel-Connected AC-DC Bidirectional Interfacing Converters
Table 1
The AC-DC converter components: the failure rates and repair time [
15].
| Component | Capacitor | IGBT | Diode | Snubber | Filter inductor | Current sensor | Voltage sensor | Gate drive | Cooling system | λtotal | μtotal | FOR |
| λone | 3.03 | 0.9 | 0.8 | 0.001 | 0.038 | 0.5 | 0.56 | 1 | 1.36 | 23.89 (Failures/106 hours) = 0.2093/year | 365/24 = 15.2/year | = 0.0136 | No. | 1 | 6 | 6 | 6 | 3 | 3 | 3 | 6 | 1 | λNo | λc = 3.03 | λIGBT = 5.4 | λD = 4.8 | λS = 0.006 | λLf = 0.114 | λI = 1.5 | λV = 1.68 | λGD = 6 | λCS = 1.36 |
|
|