Research Article
Presenting of the Magnetic Coupling-Based Transformer-Less High Step-Up DC-DC Converter for Renewable Energy Applications
Table 2
Comparison of the suggested converter and other nonisolated topologies.
| Specification | Reference [16] | Reference [17] | Reference [18] | Reference [19] | Reference [20] | Reference [21] | Reference [22] | Reference [25] | Proposed |
| Number of switches | 1 | 2 | 1 | 1 | 1 | 2 | 1 | 1 | 1 | Number of diodes | 2 | 5 | 3 | 3 | 3 | 2 | 4 | 4 | 3 | Number of inductors | 1 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 1 | Number of capacitors | 2 | 3 | 3 | 3 | 3 | 3 | 3 | 5 | 4 | Number of coupled inductors | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | M | | | | | | | | | | VS/Vo | | | | | | | | | | VD/Vo | 1 | | 1 | | | 1 | | | | Input current ripple | Low | High | High | Low | Low | Low | High | High | Low | Efficiency at 200 W (%) | 95.9 | 94.55 | 95.5 | 94 | - | 95.4 | 93.8 | 96.2 | 95.8 | Frequency (kHz) | 100 | 50 | 50 | 50 | 24 | 100 | 60 | 100 | 50 | Vo/Vin | 146/38 | 200/24 | 200/25 | 400/24 | 300/15 | 400/48 | 400/42 | 400/40 | 180/24 | N | 5 | 3 | 3 | 3 | 3 | 4 | 5 | 4 | 1.5 | Nominal power (W) | 250 | 200 | 250 | 200 | 100 | 300 | 200 | 350 | 250 | Soft switching | Yes | No | No | Yes | No | Yes | No | No | Yes |
|
|