Research Article
Adaptive Parameter Estimation for Static Var Generators Based on Wind Speed Fluctuation of Wind Farms
Table 4
Estimated parameters when the observed quantity is active power (P) or reactive power (Q).
| | Estimated parameter | Real value | Observed quantity, P | Observed quantity, Q | | Estimated value | Error (%) | Estimated value | Error (%) |
| | Kdp | 0.1E − 3 | 9.68E − 5 | 3.200 | 9.74E − 5 | 2.600 | | Kdi | 0.02 | 0.0211 | 5.500 | 0.01938 | 3.100 | | Kqp | 5 | 4.8132 | 3.376 | 4.7992 | 4.016 | | Kqi | 1000 | 999.101 | 0.089 | 988.217 | 1.178 | | KPI | 0.3 | 0.30127 | 0.420 | 0.2932 | 2.260 | | KII | 10 | 9.5521 | 4.479 | 10.149 | 1.490 | | L | 0.22 | 0.19789 | 10.05 | 0.2413 | 9.682 |
|
|