Research Article

Improved Gradient-Based Optimizer for Modelling Thermal and Hydropower Plants

Table 10

Optimized parameters and SAE of model 5.

UnitOptimized parameters using IGBOSAE (GJ/h)
a0a1a2a3a4a5RMO [24]TLBO [26]WOA [28]GBOIGBO
MinMaxSTD

1550.08.09092.7903E − 44.9979E − 8303.440.034991.4584051.5173375.02780.108640.01676940.01850414.89406E − 4
2, 3309.08.10015.5972E − 48.1159E − 8199.990.0420.5914840.7393171.50540.1394410.007270680.008065992.17061E − 4
4–9239.997.74053.2348E − 31.2692E − 7150.00.0630.4178170.4625760.88840.0216180.006363450.00686791.43248E − 4
10, 11126.08.60022.8365E − 32.4951E − 7100.00.0840.8621121.0808320.62020.01269230.009392780.01035072.66941E − 4
12, 13125.998.60052.8322E − 32.6605E − 7100.00.0840010.7831930.7995820.40790.1382050.01167180.01269362.84544E − 4