Research Article
Improved Gradient-Based Optimizer for Modelling Thermal and Hydropower Plants
Table 10
Optimized parameters and SAE of model 5.
| Unit | Optimized parameters using IGBO | SAE (GJ/h) | a0 | a1 | a2 | a3 | a4 | a5 | RMO [24] | TLBO [26] | WOA [28] | GBO | IGBO | Min | Max | STD |
| 1 | 550.0 | 8.0909 | 2.7903E − 4 | 4.9979E − 8 | 303.44 | 0.03499 | 1.458405 | 1.517337 | 5.0278 | 0.10864 | 0.0167694 | 0.0185041 | 4.89406E − 4 | 2, 3 | 309.0 | 8.1001 | 5.5972E − 4 | 8.1159E − 8 | 199.99 | 0.042 | 0.591484 | 0.739317 | 1.5054 | 0.139441 | 0.00727068 | 0.00806599 | 2.17061E − 4 | 4–9 | 239.99 | 7.7405 | 3.2348E − 3 | 1.2692E − 7 | 150.0 | 0.063 | 0.417817 | 0.462576 | 0.8884 | 0.021618 | 0.00636345 | 0.0068679 | 1.43248E − 4 | 10, 11 | 126.0 | 8.6002 | 2.8365E − 3 | 2.4951E − 7 | 100.0 | 0.084 | 0.862112 | 1.080832 | 0.6202 | 0.0126923 | 0.00939278 | 0.0103507 | 2.66941E − 4 | 12, 13 | 125.99 | 8.6005 | 2.8322E − 3 | 2.6605E − 7 | 100.0 | 0.084001 | 0.783193 | 0.799582 | 0.4079 | 0.138205 | 0.0116718 | 0.0126936 | 2.84544E − 4 |
|
|