Research Article

The Improved Unified Power Quality Conditioner with the Modular Multilevel Converter for Power Quality Improvement

Table 3

% THD of the proposed system with the harmonic order.

Order of harmonics% THD only with nonlinear load (without filter)% THD with linear and nonlinear load% THD only with nonlinear load (with filter)

1100100100
302.400
514.543.391.83
76.861.450.94
112.380.580.64
131.620.430.44
170.610.220.40
190.740.160.15