Research Article
Weighting Factor-Less Sequential Predictive Control of LC-Filtered Voltage Source Inverters
Table 4
Experimental results using two control schemes under model parameter mismatches.
| Model mismatches | Typical FS-MPC | Proposed SMPC | RMSE (V) | THD (%) | RMSE (V) | THD (%) |
| Lf, Cf | 4.60 | 1.47 | 4.96 | 1.53 | Lf, 50% Cf | 6.43 | 1.31 | 6.74 | 1.42 | 50% Lf, Cf | 8.32 | 2.38 | 6.20 | 1.90 | Lf, 200% Cf | 9.14 | 2.07 | 6.41 | 2.12 | 200% Lf, Cf | 7.44 | 1.97 | 7.93 | 2.02 |
|
|