Parameters of the inverter system.
| Parameters | Values | Parameters | Values |
| Switching frequency, fs | 20 kHz | DC-link voltage, Vdc | 190 V | Fundamental angular frequency, ωf | 100π rad/s | The bandwidth of the controller, ωc | 5500 rad/s | Filter inductance, L | 700 μH | The bandwidth of the observer, ωo | 10000 rad/s | Filter capacitance, C | 40 μF | The proportional factor of the PI controller, kp | 1.5 | ESR of the inductance, re | 0.1 Ω | Integral factor of the PI controller, ki | 100 | Voltage reference, | 156 V/0 V | Dead time, td | 1.3 μs |
|
|