Research Article
Analysis and Verification of Compound SRFPI-LADRC Strategy for an Off-Grid Single-Phase Inverter
Table 3
Performances of the three methods.
| Load type | SRFPI | LADRC | SRFPI-LADRC | THD(%) | erms(V) | Vorms(V) | THD(%) | erms(V) | Vorms(V) | THD(%) | erms(V) | Vorms(V) |
| No load | 1.60 | 1.65 | 110.52 | 2.20 | 13.40 | 111.74 | 0.87 | 1.38 | 110.52 | Nominal resistive load | 2.44 | 2.89 | 110.45 | 2.78 | 16.19 | 110.86 | 1.87 | 2.81 | 110.47 | Highly nonlinear load | 2.91 | 9.52 | 110.54 | 4.95 | 15.40 | 111.47 | 2.14 | 3.48 | 110.56 |
| No load to rated load | Voltage restore time(ms) | 1.6 | 1.2 | 0.8 |
|
|