Research Article
Diagnosis of Broken Bars in V/F Control Induction Motor Drive Using Wavelets and EEV Estimation for Electric Vehicle Applications
Table 4
Frequency and amplitude of motor current in V/F control of IM.
| Side band frequency (s = 0.045) | Estimated frequency (Hz) | Healthy state | Faulty state | Frequency (Hz) | Amplitude (dB) | Frequency (Hz) | Amplitude (dB) |
| (1–4 s) | 41 | 43 | −82 | 44 | −75 | (1-2 s) | 45.5 | 47 | −62 | 48 | −48 | (1 + 2 s) | 54.5 | 51 | −61 | 52 | −50 | (1 + 4 s) | 59 | 54 | −81 | 55 | −70 |
|
|