Research Article
[Retracted] Simulation of Flow-Induced Vibration and Dynamic Performance of Circular-Arc Helical Gear Pump under Background of Machine Learning
Table 2
Comparison of simulated flow and theoretical flow with different loads.
| Load (MPa) | No leakage theoretical flow (L/min) | There is leakage theoretical flow (L/min) | Simulation traffic (L/min) |
| 5 | 20.0172 | 19.6012 | 19.3807 | 15 | 20.0172 | 19.2499 | 19.0127 | 20 | 20.0172 | 19.0023 | 18.9935 | 25 | 20.0172 | 18.9238 | 18.001 |
|
|