Research Article

A Novel Design, Economic Assessment, and Fuzzy-Based Technical Validation of an Islanded Microgrid: A Case Study on Load Model of Kibber Village in Himachal Pradesh

Table 7

Tabulated data for the simulation model.

ParameterValue

Simulation modeNormal
Start and stop time0–4 sec.
Nominal P–P voltage (Vrms)415 V
Nominal frequency50 Hz
Sample time (s)Ts (2 e − 6)
Number of block and components240/1245
Max/Min stepAuto/Auto
Solver/Solver modeode23tb/Auto
Solver typeVariable step
Relative tolerance1 e – 3
Consecutive ZCs step relative tolerance10128eps
Max consecutive ZCs1000
Base wind speed7.2 m/s
Pitch angle
PV rating15 kW
Wind rating25 kW
Battery rating360 V/55 Ah
Solar STC1000 W/m2
Load value`25 kW
FLCStruct
TypeMamdani
And/Or methodMinMax
Defuzz methodCentroid
Imp methodMin
Agg methodMax
Input (s)/Output (s)3/1
Rule (s)75
Tip ratio (optimal)8.152