Research Article

Design and Implementation of Nonisolated High Step-Up DC-DC Converter

Table 4

Comparison of calculated and measured voltages at 200 W output power.

ParametersCalculated (V)Experimental (V)Error (%)

V C122.81920
V C275.6750.8
V C375.6750.8
V D151.66511.3
V D277.5770.65
V D377.5770.65
V Do77.5770.65
V sw77.5770.65
V out151.21500.8