Research Article

Modified Hybrid PSO Algorithm for Efficient Control of the Matrix Converter-Fed Electrical Drive System

Table 3

Proposed methods for THD comparison results for various frequencies.

FrequenciesPSOMPSOMHPSO
5 Hz50 Hz100 Hz5 Hz50 Hz100 Hz5 Hz50 Hz100 Hz

Input current harmonics (%)10.26110.36810.6589.9619.3699.1699.1238.9658.698
Output voltage harmonics (%)8.9699.028.6128.8618.127.3697.8657.687.126