Research Article
Optimization of Switching Control and Microgrid Energy Management System with Alternate Arm Converter Based on Bacterial Foraging Algorithm
Table 4
Design parameters of the proposed configuration.
| | Parameters | Values |
| | Number of solar cells per module | 96 | | Number of series-connected solar modules per string | 183 | | Number of parallel strings of solar modules | 1500 | | Wind speed | 12 m/s | | Wind power | 70 MW | | Wind generator voltage | 10,000 V | | DC voltage (Vdc) | 10,000 V | | Converter AC voltage (Vac) | 10 kV | | Arm inductor (Lu and Ll) | 100 μH | | Cell capacitance (Ccell) | 4 mF | | Cell voltage (Vcell) | 1.5 kV | | No. of cell in arm (Ncell) | 9 | | No. of series director switch (Ndir) | 5 | | Snubber capacitance (Csn) | 0.5 µF | | Snubber resistance (Rsn) | 5 kΩ | | Switching frequency (fs) | 15 kHz | | Battery voltage | 10.5 kV | | Batter rating | 5000 Ah |
|
|