Research Article

Irreversible Demagnetization of a Large Capacity Line-Start Permanent Magnet Synchronous Motors considering Influence of Permanent Magnet Temperature

Table 1

Electromagnetic parameters.

ItemsValue

Rated power (kW)630
Rated voltage (V)6000
Frequency (Hz)50
Number of poles4
Number of stator slots54
Stator external diameter (mm)740
Stator inner diameter (mm)521
Core length (mm)670
Air-gap length (mm)2
Number of rotor slots44
Moment of inertia of rotor (kg·m2)40
Moment of inertia of impeller (kg·m2)60
Iron coreDW470
PM typeN38SH
PM width (mm)69.5
PM thickness (mm)20
PM remanence at (T)1.23