Electromagnetic parameters.
| Items | Value |
| Rated power (kW) | 630 | Rated voltage (V) | 6000 | Frequency (Hz) | 50 | Number of poles | 4 | Number of stator slots | 54 | Stator external diameter (mm) | 740 | Stator inner diameter (mm) | 521 | Core length (mm) | 670 | Air-gap length (mm) | 2 | Number of rotor slots | 44 | Moment of inertia of rotor (kg·m2) | 40 | Moment of inertia of impeller (kg·m2) | 60 | Iron core | DW470 | PM type | N38SH | PM width (mm) | 69.5 | PM thickness (mm) | 20 | PM remanence at (T) | 1.23 |
|
|